013a Created with Sketch. 013c Created with Sketch. 013d Created with Sketch. 013e Created with Sketch. Group 12 Created with Sketch. Group 5 Created with Sketch. L.H Inward Created with Sketch. Group 14 Created with Sketch. Group 13 Created with Sketch. L.H Inward Created with Sketch. Group Created with Sketch. Group 12 Created with Sketch. Group Created with Sketch. L.H Inward Created with Sketch. Line Created with Sketch.

Design of Safety

After a tragic incident in 1883 in the Victoria Hall, Sunderland, the way doors were secured in public buildings needed to change. A young Robert Alexander Briggs patented a design for an automatic panic bolt which was accepted in 1892, the design overcame some of the issues that caused the loss of lives in a panic situation in a public building while maintaining security. This effective yet simplistic design, is still the basic structure for the panic bars that are used in many buildings today and has doubtless saved many lives since its introduction.

Panic Exit or Emergency Exit

There is a distinctive difference between a panic exit and an emergency exit. An emergency exit is covered by the BS EN 179 standard and is used in a building where the occupiers are likely to be familiar with the surroundings and the escape route. Examples of these would be offices with less than 60 people, private apartments or even boiler rooms.
However, within public buildings there should be conformance to BS EN 1125. In these buildings it would be expected that, although clearly marked, occupiers would be more unlikely to have knowledge of egress routes and a panic situation would be more likely to happen. This would include theatres, shopping centres, schools, hospitals and shops.

What hardware is right?

An emergency exit can include an escape lock with push to exit paddle hardware or lever handles. This is based on the idea that these buildings are likely to be locked when there is no-one in them and the users are less likely to panic due to the nature of use.
A panic exit would be covered by a horizontal panic bar, allowing for fast, easy egress, with no additional locking applied. As with the original design from 1892, when closed, doors with a panic bar are secure as the door stays locked from the outside. In the case of double doors conforming to BS EN 1125, both active and inactive leaves must be fitted with a horizontal push bar, and egress must be possible by activating either device.
There are different types of panic bars available depending on the door use. As standard the Exidor 296 provides a reliable solution, while for heavy duty usage, or high security requirements such as an LPS 1175 SR2 door the Exidor 703 would be a perfect robust option. For those who require a contemporary look which can also be used with electronic access control, Dormakaba with a stainless steel finish would look fantastic. Touch bars are also worth considering for use in specific situations as well as providing a cost-effective access controlled solution

Other Considerations

Except in a very small number of special cases, regulations state that escape doors must open in the direction of escape. This allows uninhibited egress from the building should an incident occur.

Making Your Decision

With a variety of options and levels of security available for panic hardware we can help you with your project. Contact us today to see how we can assist with your requirements.